EMIS houses sophisticated and fully equipped testing facilities for EMI/EMC testing in Bangalore, India. Our state of the art testing facility is accredited by the National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) in accordance with the standard ISO/IEC 17025:2017. We also support on-site testing in compliance with international standards.

Our wide array for testing capabilities services many industry sectors like building technology, automotives, consumer electronics, industrial technology, aviation, defence, medical electronics and telecommunication. Depending upon the application requirement, the lab is equipped for the following tests:

Test Facilities as per Commercial Specifications

Conducted Emission
Single phase up to 16A
3 phase up to 63A

This test measures the amount of electromagnetic energy that is conducted by the Product Under Test onto the power supply cords. These energy levels have to be within the prescribed limits set by the standard agencies applicable for that appropriate geographic region. This test is intended to ensure that the product under test:

Does not pollute the power supply lines

Nearby electrical devices are not affected by the device under test

Test Standard

Test Description

Range of Testing / Limits of Detection

CISPR 11/BS EN55011

Emission requirement for Industrial, Scientific & Medical Radio Frequency Equipment

150KHz to 30MHz

CISPR 14-1/BS EN 55014-1

Emission requirement for Household Appliances, Electrical tools and similar Electrical apparatus

150KHz to 30MHz

CISPR 35 / BS EN 55035

Emission requirement for multimedia equipments

150KHz to 30MHz

IEC 61000-6-3
IEC 61000-6-4

Generic standards.
Emission requirement for residential, commercial and light-industrial equipment

150KHz to 30MHz

Conducted Immunity
Single phase up to 16A
3 phase up to 32A

External EMI could come in any one of the following types – Conducted or radiated, Transient or continuous. Immunity tests are intended to qualify and quantify how immune and resilient the device under test is to external EMI. Care has to be taken by the manufacturers that their equipment has built-in features to protect itself from external EMI.

Test Standard

Test Description

Range of Testing / Limits of Detection

IEC 61000-4-2 CISPR 14-2
IEC 61000-6-1 IEC
61000-6-2 CISPR 35

Electro Static Discharge (ESD)
Contact Discharge
Air Discharge

1kV to 8kV
1kV to 16 kV

IEC 61000-4-4 CISPR 14-2
IEC 61000-6-1
IEC 61000-6-2 CISPR 35

Electrical Fast Transients (Burst)
Amplitude
Pulse duration

0.25kV to 6kV
15ms 0.75ms

IEC 61000-4-5 CISPR 14-2
IEC 61000-6-1
IEC 61000-6-2 CISPR 35

High Energy Surge
Amplitude
Pulse duration

0.25kV to 4kV
1.2 / 50μs

IEC 61000-4-1 CISPR 14-2
IEC 61000-6-1
IEC 61000-6-2 CISPR 35

Power Fail (Line Voltage Dips & Short Interruption) - Dips

230 Vrms / 415 Vrms at 50Hz / 60 Hz 0% of Uin 80% of Uin 70% of Uin 40% of Uin ½ Cycle to 250 Cycles

IEC 61000-4-6
IEC 61000-6-1
IEC 61000-6-2 CISPR 35

Conducted susceptibility on power and signal lines

9kHz to 400MHz

Radiated Emission
Open Area Test Site - 3M

This test involves measuring the electro-magnetic field strength of the emissions that are generated by any electrical product or equipment. These emissions have to be within the limit prescribed by the standards that are prevalent in that country/region.

Open Area Test Site (OATS – 3M) is the most common test to measure the EMI generated by a product under open area conditions.

Test Standard

Test Description

Range of Testing / Limits of Detection

CISPR 11/ BS EN 55011
IEC 61000-6-3
IEC 61000-6-4

Emission requirement for Industrial, Scientific & Medical Radio Frequency Equipment

30MHz to 1GHz

Harmonic Emission

This test involves measuring the harmonic currents drawn by the electrical equipments and so maintain the mains voltage quality. The harmonic current has to be within the limit prescribed by the standards.

Test Standard

Test Description

Range of Testing / Limits of Detection

IEC 61000-3-2

Harmonics Current Emission requirements for the Equipments

Single Phase up to 16A

Flicker Emission

This test involves measuring the voltage fluctuations and flicker impressed on the public low-voltage system from the device under test. Voltage fluctuations and flicker have to be within the limit prescribed by the standards.

Test Standard

Test Description

Range of Testing / Limits of Detection

IEC 61000-3-3

Voltage fluctuations and flicker requirements for the Equipments

Single Phase up to 16A

Power Frequency Magnetic Field (PFMF)

This test is performed for evaluating the performance of electrical and electronic equipment when subjected to magnetic fields at power frequency.

Test Standard

Test Description

Range of Testing / Limits of Detection

IEC 61000-8

Performance of electrical and electronic equipment

Up to 30A/m

Test Facilities as per Military Specifications

Conducted Emission
Single phase up to 50A

This test measures the amount of electromagnetic energy that is conducted by the Product Under Test onto the power supply cords. These energy levels have to be within the prescribed limits set by the standard agencies applicable for that appropriate geographic region. This test is intended to ensure that the product under test:

Does not pollute the power supply lines

Nearby electrical devices are not affected by the device under test

Test Standard

Test Description

Range of Testing / Limits of Detection

CE101–Power leads
(As per MIL-STD-461 E/F/G)

Requirements for the control of Electromagnetic Interference Characteristics of Subsystems and equipment

30Hz to 10KHz

CE102–Power leads (As per MIL-STD-461E/F/G)

Requirements for the control of Electromagnetic Interference Characteristics of Subsystems and equipment

10kHz to 10MHz

EMI/EMC Compliance Testing

Overview

EMIS houses sophisticated and fully equipped testing facilities at our EMI/EMC testing laboratory in Bangalore, India. Our EMI Testing Facility is accredited by the National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) in accordance with the standard ISO/IEC 17025:2017. We also support on-site testing.

We provide industry-specific EMC testing services. Some of the industries we cater to include:

Consumer Electronics

Defence

Medical electronics

Telecommunications

Tests at DSIR recognised R&D Lab

Hi-Pot Test
LCR Measurements
DC Resistance Test
Insulation Resistance
Temperature Rise Test
Surge withstand Test
Leakage Current Test
Overload Test
Endurance Test
Insertion Loss Test

Test Name

Test Standard

Test Range

Conducted Emission

CISPR 11, 32, 14-1, 15
IEC 61000-6-3
IEC 61000-6-4

150KHz to 30MHz
Up to 63A

Conducted Immunity

IEC 61000-4-6
CISPR 14-2, 35
IEC 61000-6-1
IEC 61000-6-2

100kHz to 400MHz

Electro static discharge

IEC 61000-4-2
CISPR 14-2,35
IEC 61000-6-1
IEC 61000-6-2

Contact Discharge: up to ±8KV
Air Discharge: Up to ±15KV

Electrical fast transient

IEC61000-4-4
CISPR 14-2,35
IEC61000-6-1
IEC61000-6-2

Up to ±6.6 KV
3 Phase Up to 32A
Power & Signal lines

Surge Immunity

IEC61000-4-5
CISPR 14-2,35
IEC61000-6-1
IEC61000-6-2

Up to ±4.4KV
3 Phase Up to 32A
Power line

Telecom Surge

IEC61000-4-5

±6.6 KV
10/700 μS
Power & Signal lines

V-Dips & Interruption

IEC61000-4-11,29
CISPR 14-2,35
IEC61000-6-1
IEC61000-6-2

3 phase Up to 32A

Power frequency magnetic field

IEC61000-4-8
CISPR 14-2,35
IEC61000-6-1
IEC61000-6-2

3 phase Up to 32A

Harmonics Emission

IEC61000-3-2
CISPR 35

Single phase up to 16A

Flicker test

IEC61000-3-3 CISPR 35

Single phase up to 16A

EMI/EMC Consulting Services

Overview

We offer a wide range of EMI/EMC services to customers to seamlessly take their products from concept to delivery. Our expert engineering and consulting team provide support to design, plan, execute, inspect and verify EMI compliant systems. EMIS can help customers with their products to meet International EMI/EMC standard compliance by providing suitable solutions within a short time span. Our EMI Consultancy Services include:

Support and guidelines for selecting the appropriate filters for various applications

EMC Control Planning EMI/EMC Product design review and compliance risk assessments

Trouble-shooting and design mitigation

Performance Requirements Definition and Flow Down Requirements

Gap Analysis Risk

Mitigation Plans Test Procedures

EMI Test Plans and Procedures Development

Trading of Critical EMI Parts

Overview

EMIs believes in delivering complete solutions to our customers. When a solution design involves components which we don’t manufacture, we procure them from reliable external sources and integrate them with our EMI solutions. So that the customer can get a one-point interface for all their needs. Externally procured components include:

EMI Suppressed circular connectors

EMI Gasket, Windows, Honeycombs and Grounding contacts

We love tinkering and finding scientific challenges to help us push our envelopes. Looking for a custom solution that is not available in our catalogue?

Request a Quote - Services

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.